Pascalstraat 80 3316 GR Dordrecht The Netherlands
Call us now
UK: +44 (0)1224 724 726
NL: +31 (0)78 6 52 41 11

AHP Range

Specification

Model No.Max Output Pressure (Bar) at airline input pressureFluid Volume Displacement per Stroke (cm3)Outlet Port ThreadWeight kgDimensions in mm
10 PSI 0.69 Bar50 PSI 3.45 Bar100 PSI 6.9 BarLengthWidthHeight
AHP106346942.31/2″ NPT23450395395
AHP26149018116.01/2″ NPT21450395395
AHP361712225012.31/2″ NPT20450395395
AHP58282004007.61/2″ NPT20450395395
AHP107623737384.01/2″ NPT20450395395
AHP1879763812932.29/16″-18UNF20450395395
AHP27515593118971.69/16″-18UNF20450395395
AHP425345144829311.09/16″-18UNF20450395395

Output Flow Rate

Hydraulic PressureApproximate Rate of Discharge (litres/min) at air input pressure 100 PSI (7 Bar)
PSIBarAHP10AHP26AHP36AHP58AHP107AHP187AHP275AHP425
0023.108.806.003.561.971.150.720.43
5003512.005.854.393.051.501.050.680.40
100069*4.723.802.511.281.000.650.38
1500104*3.903.342.381.250.900.600.36
2000138*3.003.002.251.210.780.550.34
2500173*1.212.562.051.180.750.500.33
3000207**1.951.851.160.730.480.31
4000276***1.561.020.700.450.29
5000345***1.020.950.670.420.26
7500517****0.760.600.400.25
10000690****0.440.520.370.24
150001034*****0.390.330.21
200001379******0.300.20
250001724******0.210.16
300002069*******0.13
4000027600.05

Note: * Pressure exceeds pump capacity

Clear
Add to Quote
Product added to Quote successfully!
View Quote

Description

The Patriot International AHP series of air driven hydrostatic pressure testing pumps offer a choice of eight models with output pressure capacities ranging from 6 bar (87 psi) to 2931 bar (42500 psi). All models are suitable for use with various fluids, including water and are supplied with a 150 mm diameter glycerine filled hydraulic pressure gauge (calibrated on request), inlet airline filter, lubricator and pressure regulator unit, lightweight fluid reservoir, pump start/stop valve and a robust stainless steel skid mounted framework. Optional extras include stainless steel reservoir, stroke counter system and pressure isolation valve.

  • Infinitely variable output pressure and fluid displacement speed
  • Airline regulator for easy setting of input air and output hydraulic pressure
  • Maximum air consumption 28 scfm (0.79 m3 / minute) at 7 bar
  • 7.5 litre reservoir capacity

Additional information

AHP Range

AHP107, AHP187, AHP26, AHP275, AHP36, AHP425, AHP58, APH10